gas fired 1000 kg steam hr boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :gas fired 1000 kg steam hr boiler
  • Supply Capacity : 10 units/month :gas fired 1000 kg steam hr boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Get display discount

Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Steam Generators and Fluid Heaters Clayton Industries

    Clayton is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to …Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    Calculate volume of air in m3/hr with air at 60oF and 14.7 psia pressure if boiler efficiency is 70% and FE = 1.10 A. 234,019 m3/hr B. 215,830 m3/hr C. 213,830 m3/hr D. 264,830 m3/hr 68. A windmill with a 6m radius rotor is to be installed where atmospheric pressure conditions prevail at 101.325 kPa and 21°C.Get Price

  • Complete Power Plant Power Plants for Sale Power

    3.6MW is comprised of 2 each 1,802kW GE Jenbacher natural gas fueled engine generators, model JMX 61 GS-N.L and all the power plant co-gen ancillaries, including: water exchangers, circuit pumps, the three-way valves, two environmental silencers, a Clayton SPL steam boiler of 3.000 Kg. steam/hour at 8,5 bar, a Sulzer EWK 441/09/16 5,5 kW Get Price

  • Croydon power stations - Wikipedia

    The steam capacity of the boilers was 775,000 lb/hr (97.6 kg/s). The steam conditions at the turbine stop valve were 265 / 490 psi (18.3 / 33.8 bar) and 416 / 427 °C. The overall thermal efficiency of the A station in 1963-64 was 15.33 per cent. Electricity output from Croydon A power station during its final years of operation was as follows.Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. by 8 …Get Price

  • Engineering Thermodynamics: Problems and Solutions, Chapter-4

    A steam heating system for a building 175 m high is supplied from a boiler 20 m below ground level. Dry, saturated steam is supplied from the boiler at 300 kPa, which reaches the top of the building at 250 kPa. Heat losses from the supply line to the surroundings is 50 kJ/kg. Determine (a) the quality of steam at the 175 m elevation.Get Price

  • eCFR :: 40 CFR Part 266 -- Standards for the Management of

    (2) Owners and operators of facilities that burn, in an onsite boiler or industrial furnace exempt from regulation under the small quantity burner provisions of § 266.108, hazardous waste that they generate are exempt from the regulations of parts 264, 265, 267 and 270 of this chapter applicable to storage units for those storage units that Get Price

  • eCFR :: 40 CFR Part 60 Subpart Db -- Standards of

    Temporary boiler means any gaseous or liquid fuel-fired steam generating unit that is designed to, and is capable of, being carried or moved from one location to another by means of, for example, wheels, skids, carrying handles, dollies, trailers, or platforms. A steam generating unit is not a temporary boiler if any one of the following Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    Calculate volume of air in m3/hr with air at 60oF and 14.7 psia pressure if boiler efficiency is 70% and FE = 1.10 A. 234,019 m3/hr B. 215,830 m3/hr C. 213,830 m3/hr D. 264,830 m3/hr 68. A windmill with a 6m radius rotor is to be installed where atmospheric pressure conditions prevail at 101.325 kPa and 21°C.Get Price

  • MCQ in Power Plant Engineering Part 8 | ME Board Exam

    Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hrs. to consume the available Get Price

  • Complete Combustion - an overview | ScienceDirect Topics

    Notice that for each kg of fuel entering combustion, there is 16.7 kg of air required as a minimum! In reality, more air than this must be supplied, since some excess air is required to insure complete combustion.For natural gas, an efficient boiler would use about 15 percent excess air, or roughly 19 kg per kg of fuel.Get Price

  • Chapter 24: Fuel Gas, Ohio Residential Code 2013 | UpCodes

    A boiler, completely filled with water, which furnishes hot water to be used externally to itself, and that operates at water pressures not exceeding 160 psig (1100 kPa gauge) and at water temperatures not exceeding 250°F (121°C) at or near the boiler outlet. Steam heating boiler.Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    Q is steam generated quantity, kg/hr. GCV is fuel gross calorific values. h is feed water enthalpy, A flue gas analysis of a gas-fired boiler indicates that the CO 2 content is 8% with a gas flue temperature of 204°C (400°F). Determine the overall thermal efficiency of the boiler. (with temperature up to 1000 Get Price

  • Steam Boiler | Hot Water Boiler| Industrial Steam Boilers

    Jul 29, 2021 · The ST28 steam boiler offers the following key features and optional upgrades: * Emissions fully compliant with MCPD. * Further NOx reductions achievable with the introduction of flue gas recirculation. * Output range of 1000 kg/hr to 6000 kg/hr F&A 100°C at a nett efficiency of up to 95% in accordance with EN12953.Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    Q is steam generated quantity, kg/hr. GCV is fuel gross calorific values. h is feed water enthalpy, A flue gas analysis of a gas-fired boiler indicates that the CO 2 content is 8% with a gas flue temperature of 204°C (400°F). Determine the overall thermal efficiency of the boiler. (with temperature up to 1000 Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · 4-A Coal fired boiler having total heating surface area 5200 M2 produces 18 kg of steam per square meter per hour of heating surface, then calculate the Boiler capacity in TPH. Boiler Capacity = (Heating g surface area X Steam generation per square meter) Boiler Capacity = 5200 X 18 = 93600 kg/hr =93600 / 1000 = 93.6 TPHGet Price

  • Natural Steam Methane Reforming (SMR)

    Direct Fired Heaters for Reformer & Amine Unit Energy Inputs Energy Removal kcal/hr kW kcal/hr Steam Boiler 3,742,371 Post Reformer Cooler 2,238,933 Methanator Reheat 553,190 Post HTS Cooler 1,026,525 Heat Sub-total 4,295,561 Post LTS Cooler 2,305,814 Reformer Flue Gas 648,651 Reformer 6,332,965 Sub-total 6,219,923 Amine Duty 5,680,514Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · 4-A Coal fired boiler having total heating surface area 5200 M2 produces 18 kg of steam per square meter per hour of heating surface, then calculate the Boiler capacity in TPH. Boiler Capacity = (Heating g surface area X Steam generation per square meter) Boiler Capacity = 5200 X 18 = 93600 kg/hr =93600 / 1000 = 93.6 TPHGet Price

  • Croydon power stations - Wikipedia

    The steam capacity of the boilers was 775,000 lb/hr (97.6 kg/s). The steam conditions at the turbine stop valve were 265 / 490 psi (18.3 / 33.8 bar) and 416 / 427 °C. The overall thermal efficiency of the A station in 1963-64 was 15.33 per cent. Electricity output from Croydon A power station during its final years of operation was as follows.Get Price

  • Chapter 24: Fuel Gas, 2015 Michigan Residential Code | UpCodes

    Hot water heating boiler. A boiler in which no steam is generated, from which hot water is circulated for heating purposes and then returned to the boiler, and that operates at water pressures not exceeding 160 pounds per square inch gauge (psig) (1100 kPa gauge) and at water temperatures not exceeding 250°F (121°C) at or near the boiler outlet. Hot water supply boiler.Get Price

  • Complete Power Plant Power Plants for Sale Power

    3.6MW is comprised of 2 each 1,802kW GE Jenbacher natural gas fueled engine generators, model JMX 61 GS-N.L and all the power plant co-gen ancillaries, including: water exchangers, circuit pumps, the three-way valves, two environmental silencers, a Clayton SPL steam boiler of 3.000 Kg. steam/hour at 8,5 bar, a Sulzer EWK 441/09/16 5,5 kW Get Price

  • Agricultural Anaerobic Digesters: Design and Operation

    Dec 01, 2016 · Hot water from a gas-fired standard cast-iron boiler (Figures 50, 51) was forced through the pipes by a circulation pump. The boiler was fired with LP gas for start-up and switched to biogas when production permitted. Thereafter, the boiler was operated on biogas entirely, except for its pilot light, which used LP gas continuously.Get Price

  • Steam Generators and Fluid Heaters Clayton Industries

    Clayton is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to …Get Price

  • Watt Calculator - Joules - Watts - Kilowatts - Therms

    Power-Units Conversion 1kW (KiloWatt) = 3414 BTU/hr . 0.746kW= 1hp . Power rating of steam-boliers is in units of BHP (boiler -horsepower) One BHP (Boiler Power)= 33,500 BTU/hr = 9.803 kilowatts (The Boiler-BHP power unit is a bit confusing becasue BHP could be confused with brake-horsepower (bhp) which is an auto-industry terminology)Get Price

  • Steam Boiler | Hot Water Boiler| Industrial Steam Boilers

    Jul 29, 2021 · The ST28 steam boiler offers the following key features and optional upgrades: * Emissions fully compliant with MCPD. * Further NOx reductions achievable with the introduction of flue gas recirculation. * Output range of 1000 kg/hr to 6000 kg/hr F&A 100°C at a nett efficiency of up to 95% in accordance with EN12953.Get Price

  • MCQ in Power Plant Engineering Part 8 | ME Board Exam

    Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hrs. to consume the available Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. by 8 …Get Price

  • Natural Steam Methane Reforming (SMR)

    Direct Fired Heaters for Reformer & Amine Unit Energy Inputs Energy Removal kcal/hr kW kcal/hr Steam Boiler 3,742,371 Post Reformer Cooler 2,238,933 Methanator Reheat 553,190 Post HTS Cooler 1,026,525 Heat Sub-total 4,295,561 Post LTS Cooler 2,305,814 Reformer Flue Gas 648,651 Reformer 6,332,965 Sub-total 6,219,923 Amine Duty 5,680,514Get Price

  • Complete Combustion - an overview | ScienceDirect Topics

    Notice that for each kg of fuel entering combustion, there is 16.7 kg of air required as a minimum! In reality, more air than this must be supplied, since some excess air is required to insure complete combustion.For natural gas, an efficient boiler would use about 15 percent excess air, or roughly 19 kg per kg of fuel.Get Price

  • Selective Catalytic Reduction

    High-dust arrangement (HD): The SCR unit is positioned immediately after the boiler. This configuration is used mostly in coal-fired applications, because the gas flue temperature at this location (300 - 400°C) is optimal for the catalyst activity. Dust removal is typically accomplished in cold electrostatic precipitators downstream of the SCR Get Price